"Table 1 - Weights and Measurements" "" "Stock Number","Cond. Size","Cond. Strands","Cond. Number","Diameter Over Conductor","Insulation Thickness","Jacket Thickness","Approx. OD","Copper Weight","Approx. Weight" "","AWG/Kcmil","No.","","inches","mils","mils","inches","lbs./MFT","lbs./MFT" "TBA","8","7","0","0.141","45","15","0.347","50","94" "TBA","6","7","1","0.177","45","30","0.423","81","145" "TBA","4","7","1","0.225","45","30","0.471","128","202" "TBA","2","7","1","0.282","45","30","0.558","204","307" "TBA","1","19","1","0.322","55","45","0.648","258","397" "TBA","1/0","19","1","0.361","55","45","0.687","325","475" "TBA","2/0","19","1","0.405","55","45","0.731","410","572" "TBA","3/0","19","1","0.456","55","45","0.782","518","694" "TBA","4/0","19","1","0.512","55","45","0.878","653","880" "TBA","250","37","1","0.558","65","65","0.984","771","1061" "TBA","350","37","1","0.661","65","65","1.087","1081","1409" "674244","500","37","1","0.789","65","65","1.089","1543","1798" "TBA","600","61","1","0.865","80","65","1.321","1853","2290" "TBA","750","61","1","0.968","80","65","1.424","2316","2793" "TBA","1000","61","1","1.117","80","65","1.573","3088","3624" "Table 2 - Electrical and Engineering Data" "" "Stock Number","Cond. Size","Cond. Number","Min Bending Radius","Max Pull Tension","DC Resistance @ 25C","AC Resistance @ 90C","Inductive Reactance @ 60Hz","Allowable Ampacity At 60C","Allowable Ampacity At 75C","Allowable Ampacity At 90C" "","AWG/Kcmil","","inches","lb","ohm/MFT","ohm/MFT","ohm/1000ft","Amps","Amps","Amps" "TBA","8","0","1.3","132","0.653","0.786","0.052","40","50","55" "TBA","6","1","1.6","209","0.411","0.495","0.051","55","65","75" "TBA","4","1","1.8","333","0.258","0.310","0.048","70","85","95" "TBA","2","1","2.2","530","0.162","0.195","0.045","95","115","130" "TBA","1","1","2.5","669","0.128","0.154","0.046","110","130","145" "TBA","1/0","1","2.7","844","0.102","0.122","0.044","125","150","170" "TBA","2/0","1","2.9","1064","0.081","0.097","0.043","145","175","195" "TBA","3/0","1","3.1","1342","0.064","0.078","0.042","165","200","225" "TBA","4/0","1","3.5","1692","0.051","0.062","0.041","195","230","260" "TBA","250","1","3.9","2000","0.043","0.053","0.041","215","255","290" "TBA","350","1","5.4","2800","0.031","0.039","0.040","260","310","350" "674244","500","1","5.4","4000","0.022","0.029","0.039","320","380","430" "TBA","600","1","6.6","4800","0.018","0.025","0.039","350","420","475" "TBA","750","1","7.1","6000","0.014","0.022","0.038","400","475","535" "TBA","1000","1","7.8","8000","0.011","0.018","0.037","455","545","615" "All dimensions are nominal and subject to normal manufacturing tolerances"