"Table 1 - Weights and Measurements" "" "Stock Number","Cond. Size","Cond. Strands","Cond. Number","Diameter Over Conductor","Insulation Thickness","Jacket Thickness","Approx. OD","Copper Weight","Approx. Weight" "","AWG/Kcmil","No.","","inches","mils","mils","inches","lbs./MFT","lbs./MFT" "677081","18","16","2","0.044","15","45","0.293","24","52" "588460","18","16","3","0.044","15","45","0.320","30","63" "588461","18","16","4","0.044","15","45","0.326","36","70" "588462","18","16","5","0.044","15","45","0.353","43","82" "588463","18","16","7","0.044","15","45","0.378","55","100" "630837","18","16","9","0.044","15","45","0.442","68","129" "588464","18","16","12","0.044","15","45","0.478","86","155" "598625","18","16","18","0.044","15","60","0.576","119","222" "598626","18","16","25","0.044","15","60","0.658","161","289" "677082","16","26","2","0.059","15","45","0.321","34","66" "588465","16","26","3","0.059","15","45","0.331","43","78" "588466","16","26","4","0.059","15","45","0.360","53","93" "588467","16","26","5","0.059","15","45","0.391","63","110" "588468","16","26","7","0.059","15","45","0.427","80","135" "630836","16","26","9","0.059","15","45","0.491","100","171" "588469","16","26","12","0.059","15","60","0.562","128","220" "598627","16","26","18","0.059","15","60","0.646","185","303" "598628","16","26","25","0.059","15","60","0.746","248","398" "677083","14","41","2","0.073","15","45","0.349","48","84" "588470","14","41","3","0.073","15","45","0.363","62","102" "588471","14","41","4","0.073","15","45","0.402","76","125" "588472","14","41","5","0.073","15","45","0.431","91","144" "588473","14","41","7","0.073","15","45","0.466","119","178" "598629","14","41","12","0.073","15","60","0.623","192","297" "598630","14","41","18","0.073","15","60","0.720","277","412" "598631","14","41","25","0.073","15","80","0.875","384","582" "677084","12","65","2","0.094","15","45","0.387","70","112" "677194","12","65","3","0.094","15","45","0.416","91","142" "588474","12","65","4","0.094","15","45","0.450","114","172" "588476","12","65","5","0.094","15","45","0.489","138","207" "588477","12","65","7","0.094","15","60","0.555","181","268" "677085","10","105","2","0.117","20","60","0.455","102","159" "677196","10","105","3","0.117","20","60","0.544","136","218" "588478","10","105","4","0.117","20","60","0.574","177","268" "588479","10","105","5","0.117","20","60","0.608","212","316" "588480","10","105","7","0.117","20","60","0.658","280","394" "643354","8","168","4","0.153","30","1 x 10","60","0.742","292","438" "643356","6","259","4","0.198","30","2 x 6","60","0.885","463","668" "643358","4","420","4","0.235","40","2 x 4","80","1.057","674","997" "643360","2","651","4","0.302","40","1 x 8","80","1.237","1060","1433" "Table 2 - Electrical and Engineering Data" "" "Stock Number","Cond. Size","Cond. Number","Min Bending Radius","DC Resistance @ 25C","AC Resistance @ 90C","Inductive Reactance @ 60Hz","Allowable Ampacity At 60C","Allowable Ampacity At 75C","Allowable Ampacity At 90C" "","AWG/Kcmil","","inches","ohm/MFT","ohm/MFT","ohm/1000ft","Amps","Amps","Amps" "677081","18","2","3.5","7.148","8.613","0.036","-","-","14" "588460","18","3","3.8","7.148","8.613","0.036","-","-","14" "588461","18","4","3.9","7.148","8.613","0.036","-","-","11" "588462","18","5","4.2","7.148","8.613","0.036","-","-","11" "588463","18","7","4.5","7.148","8.613","0.036","-","-","9" "630837","18","9","5.3","7.148","8.613","0.036","-","-","9" "588464","18","12","5.7","7.148","8.613","0.036","-","-","7" "598625","18","18","6.9","7.148","8.613","0.036","-","-","7" "598626","18","25","7.8","7.148","8.613","0.036","-","-","6" "677082","16","2","3.8","4.487","5.406","0.033","-","-","18" "588465","16","3","3.9","4.487","5.406","0.033","-","-","18" "588466","16","4","4.3","4.487","5.406","0.033","-","-","14" "588467","16","5","4.6","4.487","5.406","0.033","-","-","14" "588468","16","7","5.1","4.487","5.406","0.033","-","-","12" "630836","16","9","5.8","4.487","5.406","0.033","-","-","12" "588469","16","12","6.7","4.487","5.406","0.033","-","-","9" "598627","16","18","7.7","4.487","5.406","0.033","-","-","9" "598628","16","25","8.9","4.487","5.406","0.033","-","-","8" "677083","14","2","4.1","2.814","3.391","0.058","15","20","25" "588470","14","3","4.3","2.814","3.391","0.058","15","20","25" "588471","14","4","4.8","2.814","3.391","0.058","12","16","20" "588472","14","5","5.1","2.814","3.391","0.058","12","16","20" "588473","14","7","5.5","2.814","3.391","0.058","10","14","17" "598629","14","12","7.4","2.814","3.391","0.058","7","10","12" "598630","14","18","8.6","2.814","3.391","0.058","7","10","12" "598631","14","25","10.5","2.814","3.391","0.058","6","9","11" "677084","12","2","4.6","1.774","2.137","0.054","20","25","30" "677194","12","3","4.9","1.774","2.137","0.054","20","25","30" "588474","12","4","5.4","1.774","2.137","0.054","16","20","24" "588476","12","5","5.8","1.774","2.137","0.054","16","20","24" "588477","12","7","6.6","1.774","2.137","0.054","14","17","21" "677085","10","2","5.4","1.111","1.339","0.050","30","35","40" "677196","10","3","6.5","1.111","1.339","0.050","30","35","40" "588478","10","4","6.8","1.111","1.339","0.050","24","28","32" "588479","10","5","7.2","1.111","1.339","0.050","24","28","32" "588480","10","7","7.8","1.111","1.339","0.050","21","24","28" "643354","8","4","8.9","0.715","0.861","0.052","32","40","44" "643356","6","4","10.6","0.450","0.541","0.051","44","52","60" "643358","4","4","12.6","0.282","0.340","0.048","56","68","76" "643360","2","4","14.8","0.179","0.216","0.045","76","92","104" "All dimensions are nominal and subject to normal manufacturing tolerances"