"Table 1 - Weights and Measurements" "" "Stock Number","Cond. Size","Cond. Strands","Cond. Number","Diameter Over Conductor","Insulation Thickness","Ground","Jacket Thickness","Approx. OD","Copper Weight","Approx. Weight" "","AWG/Kcmil","No.","","inches","mils","No. x AWG","mils","inches","lbs./MFT","lbs./MFT" "557009","8","7","4","0.141","45","1 x 10","60","0.755","238","403" "560102","6","7","4","0.177","45","1 x 8","60","0.902","378","613" "556993","4","7","4","0.225","45","1 x 8","80","0.918","572","804" "554303","2","7","4","0.282","45","1 x 6","80","1.046","909","1185" "602011","1","19","4","0.322","55","1 x 6","80","1.202","1125","1496" "554436","1/0","19","4","0.361","55","1 x 6","80","1.299","1399","1754" "556985","2/0","19","4","0.405","55","1 x 6","80","1.420","1742","2144" "602037","3/0","19","4","0.456","55","1 x 4","80","1.521","2223","2693" "554444","4/0","19","4","0.512","55","1 x 4","110","1.721","2769","3425" "602052","250","37","4","0.558","65","1 x 4","110","1.842","3248","4003" "675713","350","37","4","0.661","65","1 x 1","110","2.081","4627","5524" "644547","350","37","4","0.661","65","1 x 3","110","2.093","4530","5437" "602078","350","37","4","0.661","65","1 x 3","110","2.095","4530","5351" "TBA","350","37","4","0.661","65","1 x 3","110","2.136","4525","5275" "672237","500","37","4","0.789","65","1 x 1/0","110","2.382","6566","7656" "675711","500","37","4","0.789","65","1 x 2/0","110","2.382","6652","7742" "672235","500","37","4","0.789","65","1 x 1","110","2.382","6498","7588" "554469","500","37","4","0.789","65","1 x 2","110","2.382","6443","7427" "672240","500","37","4","0.789","65","1 x 4/0","110","2.511","6896","8014" "675706","600","61","4","0.865","80","1 x 1/0","140","2.723","7813","9264" "665772","600","61","4","0.865","80","1 x 350","145","2.858","8575","10061" "649649","600","61","4","0.865","80","1 x 4/0","140","2.867","8144","9633" "675708","600","61","4","0.865","80","1 x 250","140","2.903","8263","9741" "570961","750","61","4","0.968","80","1 x 1","140","2.962","9616","11320" "Table 2 - Electrical and Engineering Data" "" "Stock Number","Cond. Size","Cond. Number","Min Bending Radius","Max Pull Tension","DC Resistance @ 25C","AC Resistance @ 90C","Inductive Reactance @ 60Hz","Allowable Ampacity At 60C","Allowable Ampacity At 75C","Allowable Ampacity At 90C" "","AWG/Kcmil","","inches","lb","ohm/MFT","ohm/MFT","ohm/1000ft","Amps","Amps","Amps" "557009","8","4","3.0","422","0.653","0.786","0.052","32","40","44" "560102","6","4","3.6","671","0.411","0.495","0.051","44","52","60" "556993","4","4","3.7","1068","0.258","0.310","0.048","56","68","76" "554303","2","4","5.2","1698","0.162","0.195","0.045","76","92","104" "602011","1","4","6.0","2142","0.128","0.154","0.046","88","104","116" "554436","1/0","4","6.5","2703","0.102","0.122","0.044","100","120","136" "556985","2/0","4","7.1","3407","0.081","0.097","0.043","116","140","156" "602037","3/0","4","7.6","4295","0.064","0.078","0.042","132","160","180" "554444","4/0","4","8.6","5416","0.051","0.062","0.041","156","184","208" "602052","250","4","9.2","6400","0.043","0.053","0.041","172","204","232" "675713","350","4","12.5","8960","0.031","0.039","0.040","208","248","280" "644547","350","4","12.6","8960","0.031","0.039","0.040","208","248","280" "602078","350","4","12.6","8960","0.031","0.039","0.040","208","248","280" "TBA","350","4","12.8","8960","0.031","0.039","0.040","208","248","280" "672237","500","4","14.3","12800","0.022","0.029","0.039","256","304","344" "675711","500","4","14.3","12800","0.022","0.029","0.039","256","304","344" "672235","500","4","14.3","12800","0.022","0.029","0.039","256","304","344" "554469","500","4","14.3","12800","0.022","0.029","0.039","256","304","344" "672240","500","4","15.1","12800","0.022","0.029","0.039","256","304","344" "675706","600","4","16.3","15360","0.018","0.025","0.039","280","336","380" "665772","600","4","17.1","15360","0.018","0.025","0.039","280","336","380" "649649","600","4","17.2","15360","0.018","0.025","0.039","280","336","380" "675708","600","4","17.4","15360","0.018","0.025","0.039","280","336","380" "570961","750","4","17.8","19200","0.014","0.022","0.038","320","380","428" "All dimensions are nominal and subject to normal manufacturing tolerances"