"Table 1 - Weights and Measurements" "" "Stock Number","Cond. Size","Cond. Strands","Cond. Number","Diameter Over Conductor","Insulation Thickness","Approx. OD","Copper Weight","Approx. Weight" "","AWG/Kcmil","No.","","inches","mils","inches","lbs./MFT","lbs./MFT" "597961","14","19","1","0.073","75","0.224","12","29" "597958","12","19","0","0.088","75","0.243","20","39" "579962","10","19","1","0.113","75","75","0.263","32","53" "569037","8","19","1","0.141","85","0.313","50","79" "569039","6","19","1","0.177","85","85","0.349","81","114" "569040","4","19","1","0.225","85","0.396","128","168" "569041","2","19","1","0.282","85","85","0.456","204","250" "TBA","1","19","1","0.322","105","0.532","258","331" "569043","1/0","19","1","0.361","105","0.570","326","396" "569044","2/0","19","1","0.405","105","0.614","410","488" "569045","3/0","19","1","0.456","105","105","0.664","518","604" "569047","4/0","19","1","0.512","105","0.720","655","750" "679559","250","37","1","0.558","120","120","0.782","771","879" "653096","300","37","1","0.610","120","120","0.851","926","1051" "590138","350","37","1","0.661","120","0.901","1080","1215" "578324","500","37","1","0.789","120","1.006","1543","1685" "672530","600","61","1","0.865","135","1.136","1852","2042" "TBA","750","61","1","0.968","135","1.238","2316","2560" "TBA","1000","61","1","1.117","135","1.387","3088","3365" "Table 2 - Electrical and Engineering Data" "" "Stock Number","Cond. Size","Cond. Number","Min Bending Radius","DC Resistance @ 25C","AC Resistance @ 90C","Inductive Reactance @ 60Hz","Allowable Ampacity At 60C","Allowable Ampacity At 75C","Allowable Ampacity At 90C" "","AWG/Kcmil","","inches","ohm/MFT","ohm/MFT","ohm/1000ft","Amps","Amps","Amps" "597961","14","1","0.9","2.631","3.170","0.058","15","20","25" "597958","12","0","1.0","1.662","2.002","0.054","20","25","30" "579962","10","1","1.1","1.040","1.253","0.050","30","35","40" "569037","8","1","1.3","0.653","0.786","0.052","40","50","55" "569039","6","1","1.4","0.411","0.495","0.051","55","65","75" "569040","4","1","1.6","0.258","0.310","0.048","70","85","95" "569041","2","1","1.8","0.162","0.195","0.045","95","115","130" "TBA","1","1","2.1","0.128","0.154","0.046","110","130","145" "569043","1/0","1","2.3","0.102","0.122","0.044","125","150","170" "569044","2/0","1","2.5","0.081","0.097","0.043","145","175","195" "569045","3/0","1","2.7","0.064","0.078","0.042","165","200","225" "569047","4/0","1","2.9","0.051","0.062","0.041","195","230","260" "679559","250","1","3.1","0.043","0.053","0.041","215","255","290" "653096","300","1","3.4","0.036","0.045","0.041","240","285","320" "590138","350","1","3.6","0.031","0.039","0.040","260","310","350" "578324","500","1","5.0","0.022","0.029","0.039","320","380","430" "672530","600","1","5.7","0.018","0.025","0.039","350","420","475" "TBA","750","1","6.2","0.014","0.022","0.038","400","475","535" "TBA","1000","1","6.9","0.011","0.018","0.037","455","545","615" "All dimensions are nominal and subject to normal manufacturing tolerances"