"Table 1 - Weights and Measurements" "" "Stock Number","Cond. Size","Conductor Number","Conductor Stranding","Diameter Over Conductor","Insul. Thickness","Diameter Over Insulation","Diameter Over Insulation Shield","Ground","Jacket Thickness","Approx. OD","Approx. Weight","Max Pull Tension","Min Bending Radius" "","AWG/Kcmil","","","inches","mils","inches","inches","No. x AWG","mils","inches","lbs./MFT","lbs.","inches" "599300","2","3","6","0.268","220","0.746","0.806","1x4","110",2.012,"1783","1194","14.0" TBA,"1","3","19","0.298","220","0.776","0.836","1x6","110",2.080,"1726","1506","14.5" TBA,"1/0","3","19","0.336","220","0.814","0.874","1x6","110",2.163,"1876","1900","15.1" TBA,"2/0","3","19","0.376","220","0.854","0.914","1x4","110",2.249,"2094","2395","15.7" "599305","3/0","3","15","0.422","220","0.901","0.961","1x4","110",2.354,"2442","3020","16.4" "675662","4/0","3","19","0.474","220","0.953","1.013","1x4","110",2.466,"2672","3808","17.2" TBA,"250","3","35","0.520","220","1.006","1.066","1x4","110",2.577,"2794","4500","18.0" TBA,"350","3","35","0.615","220","1.101","1.161","1x3","135",2.832,"3479","6300","19.8" TBA,"500","3","35","0.735","220","1.221","1.281","1x2","135",3.092,"4262","9000","21.6" TBA,"750","3","58","0.908","220","1.404","1.464","1x1","135",3.487,"5535","13500","24.4" "669197","750","3","53","0.908","220","1.416","1.476","1x1","135",3.516,"5671","10000","24.4" "All dimensions are nomial and subject to normal manufacturing tolerances" "Table 2 - Electrical and Engineering Data" "Cond. Size","DC Resistance @ 25C","AC Resistance @ 90C","Capacitive Reactance","Inductive Reactance","Zero Sequence Impedance","Positive Sequence Impedance","Shield Short Circuit Current 6 Cycles","Allowable Ampacity In Duct 90/105C","Allowable Ampacity In Air 90/105C" "AWG/Kcmil","ohm/MFT","ohm/MFT","Mohm*MFT","Mohm/MFT","ohm/MFT","ohm/MFT","Amps","Amps","Amps" "2","0.267","0.336","0.053","0.048","0.711 + j0.427","0.336 + j0.047","2528","115/125","125/145" "1","0.211","0.266","0.049","0.046","0.64 + j0.411","0.266 + j0.044","2621","135/145","145/165" "1/0","0.168","0.211","0.046","0.044","0.584 + j0.394","0.211 + j0.043","2738","150/165","170/185" "2/0","0.133","0.167","0.042","0.043","0.538 + j0.377","0.167 + j0.041","2862","170/185","190/215" "3/0","0.105","0.133","0.039","0.041","0.501 + j0.358","0.133 + j0.04","3005","195/210","220/245" "4/0","0.084","0.105","0.036","0.040","0.469 + j0.339","0.105 + j0.038","3166","220/240","255/285" "250","0.071","0.090","0.034","0.039","0.45 + j0.321","0.09 + j0.037","3333","245/265","280/315" "350","0.050","0.065","0.030","0.037","0.417 + j0.291","0.065 + j0.035","3628","295/315","345/385" "500","0.035","0.046","0.026","0.035","0.386 + j0.26","0.046 + j0.033","3999","355/385","425/475" "750","0.024","0.033","0.022","0.033","0.355 + j0.22","0.034 + j0.031","4566","440/475","540/600" "750","0.024","0.033","0.022","0.033","0.355 + j0.22","0.034 + j0.031","4566","440/475","540/600"