"Table 1 - Weights and Measurements" "" "Stock Number","Cond. Size","Conductor Number",,"Conductor Shape","Strand Count","Insulation Thickness","Approx. OD","Copper Weight","Approx. Weight" "","AWG/Kcmil","","","No. of Strands","mils","inches","lbs./MFT","lbs./MFT" 643665,"14","1","7","45","0.164","12","24" 643666,"12","1","7","45","0.183","20","33" 643667,"10","1","7","45","0.207","32","47" 643668,"8","1","7","60","0.268","50","77" 643669,"6","1","7","60","0.304","81","112" 643670,"4","1","7","60","0.351","128","167" 646618,"3","1","7","60","0.378","162","204" 643671,"2","1","7","60","0.409","204","251" 643672,"1","1","19","80","0.490","258","329" 643673,"1/0","1","19","80","0.530","326","404" 643674,"2/0","1","19","80","0.574","410","497" 643675,"3/0","1","19","80","0.624","518","614" 643677,"4/0","1","19","80","0.680","653","759" 643678,"250","1","37","95","0.758","771","909" 643679,"350","1","37","95","0.841","1080","1236" 557136,"500","1","37","95","0.989","1543","1733" 643680,"500","1","37","95","0.989","1543","1731" 647653,"600","1","61","110","1.098","1852","2090" 643826,"750","1","61","110","1.200","2315","2579" 643827,"1000","1","61","110","1.349","3087","3388" "All dimensions are nominal and subject to normal manufacturing tolerances" "Table 2 - Electrical and Engineering Data" "Stock Number","Cond. Size","Min Bending Radius","Max Pull Tension/Rated Braking Strength","DC Resistance @ 25C","AC Resistance @ 90C","Inductive Reactance","Short Circuit Current 6 Cycles","Allowable Ampacity At 60C","Allowable Ampacity At 75C","Allowable Ampacity At 90C" "","AWG/Kcmil","inches","lbs.","ohm/MFT","ohm/MFT","ohm/MFT","Amps","Amps","Amps","Amps" 643665,"14","0.6","32","2.631","3.170","0.058","","15","20","25" 643666,"12","0.7","52","1.662","2.002","0.054","","20","25","30" 643667,"10","0.8","83","1.040","1.253","0.050","","30","35","40" 643668,"8","1.0","132","0.653","0.786","0.052","","40","50","55" 643669,"6","1.2","209","0.411","0.495","0.051","","55","65","75" 643670,"4","1.4","333","0.258","0.310","0.048","","70","85","95" 646618,"3","1.5","420","0.205","0.246","0.047","","85","100","115" 643671,"2","1.6","530","0.162","0.195","0.045","","95","115","130" 643672,"1","1.9","669","0.128","0.154","0.046","","110","130","145" 643673,"1/0","2.1","844","0.102","0.122","0.044","","125","150","170" 643674,"2/0","2.2","1064","0.081","0.097","0.043","","145","175","195" 643675,"3/0","2.4","1342","0.064","0.078","0.042","","165","200","225" 643677,"4/0","2.7","1692","0.051","0.062","0.041","","195","230","260" 643678,"250","3.0","2000","0.043","0.053","0.041","","215","255","290" 643679,"350","3.3","2800","0.031","0.039","0.040","","260","310","350" 557136,"500","3.9","4000","0.022","0.029","0.039","","320","380","430" 643680,"500","3.9","4000","0.022","0.029","0.039","","320","380","430" 647653,"600","5.4","4800","0.018","0.025","0.039","","350","420","475" 643826,"750","6.0","6000","0.014","0.022","0.038","","400","475","535" 643827,"1000","6.7","8000","0.011","0.018","0.037","","455","545","615"