SPEC 42090

TGGTG CABLES

TGGTG Power Cable - Flexible Premium High Temperature Cable, Temp Rating 250°C, 600V

...

Construction:

  1. Conductor:Flexible stranded nickel plated, annealed copper
  2. Insulation:PTFE Fluoropolymer tapes covered by wrapped fiberglass yarn
  3. Braid:Fiberglass braid jacket is applied over the insulation
  4. Cabling:Conductors are cabled with a left hand lay and bound with a polyester tape
  5. Jacket:Fiberglass braid jacket is applied over the insulation, then treated with a high temperature saturant

Applications and Features:

Used in wiring equipment.

Excellent flame resistance, good weathering, sunlight, ozone, and corona resistance, and good flexibility without cold flow. Also available in Power and Instrumentation Cables.

Specifications:

  • RoHS-3 Complies with European Directive 2015/863
  • Table 1 – Weights and Measurements
    Stock NumberCond. SizeCond. NumberApprox. ODApprox. WeightTemp. RatingStandard (UL or other)
    AWG/KcmilNo.inchlb/1000ft°CStyle/Type
    C532001620.28038250UL
    C532051630.30057250UL
    C532101640.33575250UL
    C532151650.37093250UL
    C532201670.410129250UL
    C5323016120.560219250UL
    C5324016190.675342250UL
    C5325016370.905659250UL
    C533001420.31050250UL
    C533051430.33075250UL
    C533101440.37099250UL
    C522151450.410122250UL
    C533201470.455172250UL
    C5333014120.615293250UL
    C5334014190.750450250UL
    C534001220.34067250UL
    C534051230.365101250UL
    C534101240.405133250UL
    C534151250.450166250UL
    C534201270.500231250UL
    C5343012120.680393250UL
    C5344012190.815618250UL
    C535001020.460114250UL
    C535051030.495170250UL
    C535101040.545222250UL
    C535151050.630292250UL
    C535201070.675374250UL
    C5353010120.930648250UL
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    Table 2 – Weights and Measurements (Metric)
    Stock NumberCond. SizeCond. NumberApprox. ODApprox. WeightTemp. RatingStandard (UL or other)
    AWG/KcmilNo.mmkg/km°CStyle/Type
    C532001627.1157250UL
    C532051637.6285250UL
    C532101648.51112250UL
    C532151659.40138250UL
    C5322016710.41192250UL
    C53230161214.22326250UL
    C53240161917.15509250UL
    C53250163722.99981250UL
    C533001427.8774250UL
    C533051438.38112250UL
    C533101449.40147250UL
    C5221514510.41182250UL
    C5332014711.56256250UL
    C53330141215.62436250UL
    C53340141919.05670250UL
    C534001228.64100250UL
    C534051239.27150250UL
    C5341012410.29198250UL
    C5341512511.43247250UL
    C5342012712.70344250UL
    C53430121217.27585250UL
    C53440121920.70920250UL
    C5350010211.68170250UL
    C5350510312.57253250UL
    C5351010413.84330250UL
    C5351510516.00435250UL
    C5352010717.15557250UL
    C53530101223.62964250UL

    Revision: 1.000.000

    Updated On: Dec. 11, 2023, 9:29 p.m. UTC