SPEC 42023

FEP 200°C 1000V UL 10203

UL/CSA Approved Lead Wire, Temp Rating 200°C

...

Construction:

  1. Conductor:Stranded tinned, annealed copper per ASTM B33
  2. Insulation:Extruded FEP fluoropolymer

Applications and Features:

Used for internal wiring of appliances. This product is suitable for immersion in gasoline, gasoline vapor, and immersion in oil to 80°C. Excellent chemical resistance, excellent resistance to fluids, and low coefficient of friction makes installation easier. Good mechanical strength. Available in all colors.

Specifications:

  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL AWM Appliance wire approvals as listed in Table 1
  • CSA AWM I A/B 600 FT1 FT2
  • Table 1 – Weights and Measurements
    Stock NumberCond. SizeCond. StrandsInsul. ThicknessApprox. ODApprox. WeightTemp. RatingStandard (UL or other)
    AWG/Kcmilstrandmilinchlb/1000ft°CStyle/Type
    C3229Z22*7/.0100200.070520010203
    C3209Z20*7/.0126200.080720010203
    C3189A187/.0152200.0901020010203
    C3169A167/.0192200.1001320010203
    C3149A147/.0242200.1101720010203
    C3129A1219/.0179200.1302520010203
    C3109A1037/.0159200.1603520010203
    C3089A854/.0179300.2206020010203
    C3069A684/.0179300.2359520010203
    C3049A4133/.0177300.29514520010203
    C3029A2133/.0223300.34022020010203
    C3019A1259/.0177450.46032020010203
    C31T9A1/0259/.0202450.48536020010203
    C32T9A2/0259/.0229450.51546020010203
    C33T9A3/0259/.0255450.57556520010203
    C34T9A4/0259/.0286450.67575520010203

    All dimensions are nominal and subject to normal manufacturing tolerances

    ◊ Cable marked with this symbol is a standard stock item

    Dimensions and weights for other cable configurations are available upon request.
    *NPC Conductor required for 200°C Rating

    Table 2 – Weights and Measurements (Metric)
    Stock NumberCond. SizeCond. StrandsInsul. ThicknessApprox. ODApprox. WeightTemp. RatingStandard (UL or other)
    AWG/Kcmilstrandmmmmkg/km°CStyle/Type
    C3229Z22*7/.01000.511.78720010203
    C3209Z20*7/.01260.512.031020010203
    C3189A187/.01520.512.291520010203
    C3169A167/.01920.512.541920010203
    C3149A147/.02420.512.792520010203
    C3129A1219/.01790.513.303720010203
    C3109A1037/.01590.514.065220010203
    C3089A854/.01790.765.598920010203
    C3069A684/.01790.765.9714120010203
    C3049A4133/.01770.767.4921620010203
    C3029A2133/.02230.768.6432720010203
    C3019A1259/.01771.1411.6847620010203
    C31T9A1/0259/.02021.1412.3253620010203
    C32T9A2/0259/.02291.1413.0868520010203
    C33T9A3/0259/.02551.1414.6084120010203
    C34T9A4/0259/.02861.1417.15112420010203

    Revision: 1.0.00M