SPEC 45551

CU 600V PE PVC Cable Color Method 1 Table 1 Traffic Signal IMSA 19-1

Multi-conductor nonshielded 600V Polyethylene Insulation, Polyvinyl Chloride (PVC) Jacket

...

Construction:

  1. Conductor:Solid or stranded annealed bare copper class B per ASTM B3 and B8
  2. Insulation:Polyethylene PE
  3. Rip Chord:High strength rip chord for ease of jacket removal
  4. Separator:Polyester tape
  5. Jacket:Black polyvinyl chloride PVC jacket

Applications and Features:

Southwire’s IMSA 19-1 cable meets the requirements of International Municipal Signal Association IMSA 19-1 specification. Rated for use in traffic signal, traffic control systems, underground conduit and aerial use where supported by a messenger. IMSA 19-1 600 Volt series cables run from the traffic light to the controller station The conductors are bare annealed copper solid or stranded class B and covered with an abrasion, sunlight and moisture resistant polyvinyl chloride jacket. The insulated conductors are twisted and wrapped with a polyester tape. A ripcord is added under the black polyvinyl chloride jacket for ease of removal. These cables are capable of operating continuously at a conductor temperature between -20°C and 75°C.

• Cable is manufactured by Southwire Company in their Waukegan, IL plant USA.

Specifications:

  • ASTM B3 Standard Specification for Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B174 Standard Specification for Bunch-Stranded Copper Conductors
  • EPA 40 CFR, Part 26, Subpart C heavy metals per Table 1, TCLP method
  • IMSA 19-1
  • Sample Print Legend:

    SOUTHWIRE® YEAR SIZE 600V IMSA 19-1 CABLE SEQUENTAIL FOOT MARK.
    Table 1 – Weights and Measurements
    Stock NumberCond. SizeCond. NumberCond. StrandsDiameter Over ConductorInsul. ThicknessJacket ThicknessApprox. ODApprox. Weight
    AWG/KcmilConductorsNo.inchmilmilinchlb/1000ft
    TBA16210.05125450.28343
    TBA16270.05625450.29545
    TBA16310.05125450.31457
    TBA16370.05625450.33060
    TBA16410.05125450.34470
    TBA16470.05625450.36474
    TBA16510.05125450.37684
    TBA16570.05625450.39588
    TBA16710.05125450.406109
    TBA16770.05625450.428114
    TBA16910.05125450.470139
    TBA16970.05625450.496143
    TBA161210.05125450.548192
    TBA161270.05625450.578198
    59312414210.06425450.31862
    59312514310.06425450.33574
    58138414270.0725450.33667
    57892414370.0725450.35479
    57904714410.06425450.36593
    58139614470.0725450.38699
    59312614510.06425450.398114
    57888914570.0725450.422122
    59312714710.06425450.432146
    57889014770.0725450.459156
    TBA14910.06425600.503188
    58139914970.0725600.565216
    TBA141010.06425600.576221
    TBA141210.06425600.593255
    TBA141070.0725600.612235
    TBA141270.0725600.630272
    TBA141610.06425600.656328
    578928141670.0725600.698350
    TBA142010.06425600.725398
    TBA142110.06425600.725410
    TBA142070.0725600.773424
    578892142170.0725600.773455
    TBA12210.08025450.37289
    TBA12310.08025450.393107
    TBA12270.08725450.39495
    TBA12370.08725450.417113
    TBA12410.08025450.430135
    TBA12470.08725450.456143
    TBA12510.08025450.471168
    TBA12570.08725450.500178
    TBA12710.08025600.513232
    TBA12770.08725600.576246
    TBA12910.08025600.630297
    TBA12970.08725600.670315
    TBA121210.08025600.705377
    TBA121270.08725600.751399
    TBA121610.08025800.783490
    TBA121670.08725800.874552

    All dimensions are nominal and subject to normal manufacturing tolerances

    ◊ Cable marked with this symbol is a standard stock item

    Table 2 – Electrical and Engineering Data
    Stock NumberCond. SizeCond. NumberMin Bending RadiusDC Resistance @ 25°C
    ConductorsAWG/KcmilinchΩ/1000ft
    TBA1621.134.14
    TBA1621.184.18
    TBA1631.264.14
    TBA1631.324.18
    TBA1641.384.14
    TBA1641.464.18
    TBA1651.504.14
    TBA1651.584.18
    TBA1671.624.14
    TBA1671.714.18
    TBA1691.884.14
    TBA1691.984.18
    TBA16122.194.14
    TBA16122.314.18
    5931241421.272.57
    5931251431.342.57
    5813841421.342.63
    5789241431.422.63
    5790471441.462.57
    5813961441.542.63
    5931261451.592.57
    5788891451.692.63
    5931271471.732.57
    5788901471.842.63
    TBA1492.012.57
    5813991492.262.63
    TBA14102.302.57
    TBA14122.372.57
    TBA14102.452.63
    TBA14122.522.63
    TBA14162.622.57
    57892814162.792.63
    TBA14202.902.57
    TBA14212.902.57
    TBA14203.092.63
    57889214213.092.63
    TBA1221.491.62
    TBA1231.571.62
    TBA1221.581.66
    TBA1231.671.66
    TBA1241.721.62
    TBA1241.821.66
    TBA1251.881.62
    TBA1252.001.66
    TBA1272.051.62
    TBA1272.301.66
    TBA1292.521.62
    TBA1292.681.66
    TBA12122.821.62
    TBA12123.001.66
    TBA12163.131.62
    TBA12163.501.66