SPEC 85079

2/C, 3/C, 4/C CU 600 V FR-XLPE Shielded PVC Jacket Power Cable With Ground. Color Method 1 Table 2

Type TC-ER Power Cable 600 or 1000 Volt Three Conductor Copper, Fire Retardant Cross-Linked Polyethylene (FR-XLPE) insulation Shielded Polyvinyl Chloride (PVC) Jacket with 1 Bare CU Ground. Conductor Identification Method 1 Table 2

...

Construction:

  1. Conductor:Class B compressed stranded bare copper per ASTM B3 and ASTM B8
  2. Insulation:Fire Retardant Cross Linked Polyethylene (FR-XLPE)
  3. Filler:Paper or Polypropylene filler
  4. Binder:Polyester flat thread binder tape
  5. Shield:5 mils tape shield
  6. Rip Chord:Rip chord for ease of jacket removal
  7. Overall Jacket:Polyvinyl Chloride (PVC) Jacket

Applications and Features:

Southwire’s 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.

Specifications:

  • ASTM B3 Standard Specification for Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1277 Electrical Power and Control Tray Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
  • CSA CSA marking is available upon request
  • ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu/hr) and ICEA T-29-520 - (210,000 Btu/hr)
  • Sample Print Legend:

    SOUTHWIRE E75755 {UL} XX AWG X/C FR-XLPE TYPE TC-ER CDRS 90C SHIELDED PVC JKT 600V SUN RES DIRECT BURIAL {YYYY} {SEQUENTIAL FOOTAGE MARKS} SEQ FEET
    Table 1 – Physical and Electrical Data
    Stock NumberCond. SizeCond. NumberCond. StrandsDiameter Over Cond.Insul. ThicknessDiameter Over InsulationJacket ThicknessApprox. ODApprox. WeightDC ResistanceAC Resistance @ 90°CMin Bending RadiusAllowable Ampacity At 60°C *Allowable Ampacity 75°C *Allowable Ampacity 90°C *
    AWGNo.strandsinchmilinchmilinchlb/1000ftΩ/1000ftΩ/1000ftinchAmpAmpAmp
    TBA8270.139450.229600.592060.6520.8152.4405055
    TBA8370.139450.229600.6152750.6520.8152.5405055
    TBA8470.139450.229600.6733470.6520.8152.7324044
    TBA6270.174450.264600.6612850.4110.5142.6556575
    TBA6370.174450.264600.6913940.4110.5142.8556575
    6721126470.174450.264600.7955700.4110.5143.0445260
    6207386470.174450.264800.8395820.4110.5143.5445260
    TBA4270.221450.311600.7534090.2580.3233708595
    TBA4370.221450.311600.7915570.2580.3233.2708595
    6626384470.221450.311800.9388260.2580.3234.0566876
    TBA2270.277450.367800.9076300.1620.2033.695115130
    TBA2370.277450.367800.9538610.1620.2033.895115130
    TBA2470.277450.367801.04711090.1620.2035.27692104
    TBA12190.321550.431801.0367890.1290.1615.2110130145
    TBA13190.321550.431801.09110790.1290.1625.5110130145
    TBA14190.321550.431801.20013920.1290.1616.088104116
    TBA1/02190.36550.47801.1169560.1020.1285.6125150150
    TBA1/03190.360550.470801.17513170.1020.1285.9125150170
    TBA1/04190.360550.470801.29517040.1020.1286.5100120136
    TBA2/02190.404550.515801.20211620.0810.1016145175195
    TBA2/03190.404550.514801.27016130.0810.1026.4145175195
    TBA2/04190.404550.514801.40120930.0810.1017.0116140156
    TBA3/02190.454550.564801.30414220.0640.086.5165200225
    TBA3/03190.454550.564801.37819860.0640.0816.9165200225
    TBA3/04190.454550.564801.52125820.0640.0807.6132160180
    TBA4/02190.51550.62801.41617440.0510.0647.1195230260
    TBA4/03190.510550.620801.49924490.0510.0647.5195230260
    TBA4/04190.510550.620801.65731910.0510.0648.3156184208
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item

    Revision: 3.0.00C