SPEC 85013

Multi-Conductor CU 600 V PE/PVC Insulation PVC Jacket Control Cable Color Method 1 Table 1

Control Cable 600 Volt Copper Conductors, Polyethylene and Polyvinyl Chloride (PE/PVC) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free

...

Construction:

  1. Conductor:7 strands class B compressed bare copper per ASTM B3 and ASTM B8
  2. Insulation:Polyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes
  3. Filler:Polypropylene filler on cables with 5 or less conductors
  4. Binder:Polyester flat thread binder tape applied for cables with more than 5 conductors
  5. Rip Chord:Rip chord for ease of jacket removal
  6. Overall Jacket:Polyvinyl Chloride (PVC) Jacket

Applications and Features:

Southwire’s 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.

Specifications:

  • ASTM B3 Standard Specification for Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • CSA CSA marking is available upon request
  • ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1
  • ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu/hr) and ICEA T-29-520 - (210,000 Btu/hr)
  • VW-1 (Vertical-Wire) Flame Test
  • Sample Print Legend:

    Non UL Listed
    SOUTHWIRE XX AWG X/C PE/PVC CDRS 75C PVC JACKET SUNLIGHT RESISTANT DIRECT BURIAL 600V {MM/DD/YYYY} {SEQUENTIAL FOOTAGE MARKS} SEQ FEET

    Table 1 – Physical and Electrical Data
    Stock NumberCond. SizeCond. NumberDiameter Over Cond.Insul. ThicknessJacket ThicknessApprox. ODCopper WeightApprox. WeightDC ResistanceAC Resistance @ 90°CMin Bending RadiusAllowable Ampacity At 60°C *Allowable Ampacity 75°C *Allowable Ampacity 90°C *
    AWGNo.inchmilmilinchlb/1000ftlb/1000ftΩ/1000ftΩ/1000ftinchAmpAmpAmp
    14 AWG
    TBA1420.07030450.34926682.6303.2881.4151515
    TBA1430.07030450.37038872.6303.2881.5151515
    6206461440.07030450.403511092.6303.2881.6141515
    TBA1450.07030450.440641322.6303.2881.8141515
    TBA1460.07030450.479771552.6303.2881.9141515
    6067761470.07030450.479901712.6303.2881.9121515
    TBA1480.07030450.5191021952.6303.2882.1121515
    TBA1490.07030600.5881152362.6303.2882.4121515
    TBA14100.07030600.6381282662.6303.2882.691112
    60677714120.07030600.6591543032.6303.2882.691112
    TBA14150.07030600.7301923712.6303.2882.991112
    TBA14190.07030600.7682434462.6303.2883.191112
    TBA14200.07030600.8082564752.6303.2883.291112
    TBA14250.07030800.9373206192.6303.2883.78911
    TBA14300.07030800.9913847192.6303.2884.08911
    TBA14370.07030801.0674748622.6303.2885.37810
    12 AWG
    6187211220.08730450.38441901.6602.0751.5202020
    TBA1230.08730450.408611181.6602.0751.6202020
    6168561240.08730450.445811481.6602.0751.8162020
    6174161250.08730600.5371021881.6602.0752.0162020
    6191731260.08730450.5321222141.6602.0752.1162020
    6174211270.08730600.5821432471.6602.0752.3141720
    577810#1270.08745600.6681432721.6602.0752.7141720
    TBA1280.08730600.6071632881.6602.0752.4141720
    6193821290.08730600.6511833241.6602.0752.6141720
    TBA12100.08730600.7092043651.6602.0752.8101215
    619993^12120.08730600.7522443961.6602.0752.9101215
    61742012120.08730600.7592443961.6602.0752.9101215
    TBA12150.08730600.8133055161.6602.0753.3101215
    TBA12190.08730800.8963876571.6602.0753.6101215
    TBA12200.08730800.9424076991.6602.0753.8101215
    TBA12250.08730801.0435098601.6602.0755.291113
    TBA12300.08730801.10461110051.6602.0755.591113
    TBA12370.08730801.19175312111.6602.0756.081012
    10 AWG
    6187191020.11130450.431651241.0401.3001.7303030
    6191171030.11130450.459971651.0401.3001.8303030
    6187201040.11130600.5401302231.0401.3002.2242830
    6167331040.11130600.5521302251.0401.3002.2242830
    TBA1050.11130600.5811622731.0401.3002.3242830
    TBA1060.11130600.6321943231.0401.3002.5242830
    6189681070.11130600.6322273581.0401.3002.5212428
    6191791080.11130600.6852594101.0401.3002.7212428
    6067821090.11130600.7362914611.0401.3002.9212428
    61918110100.11130600.8033245191.0401.3003.2151720
    61891110120.11130600.8303896001.0401.3003.3151720
    TBA10150.11130800.9644867771.0401.3003.9151720
    TBA10190.11130801.0146159411.0401.3005.1151720
    TBA10200.11130801.06764810011.0401.3005.3151720
    TBA10250.11130801.18481012361.0401.3005.9131518
    TBA10300.11130801.25497114501.0401.3006.3131518
    TBA10370.11130801.355119817551.0401.3006.8121416
    617347920.12730450.472651350.8090.9961.9354550
    617349940.12730600.579652470.8090.9962.3283640
    617350980.12730600.747654470.8090.9963.0253236
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    * Ampacities are based on Table 310.15 (B)(16) of the NEC, 2017 Edition. Ampacities of insulated conductors rated up to and including 2000 Volts, based on ambient temperature of 30°C (86°F)
    ^ 19 Strand Class C
    # 1000 Volts

    Revision: 3.0.00C