SPEC 44020

1/C CU 2000V EPR RHH/RHW-2 CPE Power Cable HDFPC-DLO RW90

UL Listed as 2kV Heavy Duty Flexible Power Cable (HDFPC) DLO, Rated 90°C Dry or Wet. 2kV Type RHH/RHW-2 Flexible Power Cable Rated for Dry or Wet. CSA Listed as 2kV Type RW90. Composite Thermoset Wall EPDM/CPE Insulation/Jacket.

...

Construction:

  1. Conductor:Flexible Stranded Rope-Lay Class I Tinned Copper per ASTM B33 and B172
  2. Binder Tape:Mylar Tape
  3. Insulation:2 layer Thermoset Ethylene Propylene Diene Monomer / Thermoset Chlorinated Polyethylene (EPDM/CPE)

Applications and Features:

HDFPC-DLO is a 2kV flexible power cable with a variety of possible applications such as but not limited to: Drilling rigs, railroad and transit car wiring, mining and other industrial equipment, and as flexible motor leads and wind turbine applications. The cable is suited for use in wet and dry areas, conduits, ducts, troughs, trays, and where superior electrical properties are desired. HDFPC-DLO is oil, heat, flame, abrasion, and sunlight resistant. Approved for use per the NEC® as Type RHH/RHW-2 and per the CE Code as 2kV Type RW90. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Sizes 1/0 and Larger Rated For CT Use.

Specifications:

  • ASTM B3 Standard Specification for Soft or Annealed Copper Wire
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors (As Applicable)
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • UL 2806 Heavy Duty Flexible Power Cable (HDFPC-DLO)
  • CSA C22.2 No. 38 Thermoset-insulated wires and cables Type RW90
  • CSA C22.2 No.230 Tray Cables - Rated TC-ER (1/0 AWG and Larger)
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
  • MSHA Approved
  • Sample Print Legend:

    SOUTHWIRE® xxx SIZE AWG (xxx mm2) EPR/CPE 2KV HDFPC-DLO TYPE RHH OR RHW-2 (-40°C) PRII SUN RES FOR CT USE (UL) E30117 (CSA LOGO) LL90458 RW90 EP 2KV (-40°C) EP/CPE TC FT4 --- P-07-KA100013-MSHA SEQUENTIAL FOOTAGE MARKS.
    Table 1 – Weights and Measurements
    Stock NumberCond. SizeStrand CountDiameter Over ConductorInsul. ThicknessApprox. ODCopper WeightApprox. Weight
    AWG/KcmilNo. of Strandsinchmilinchlb/1000ftlb/1000ft
    57125312190.090600.2102036
    56005710260.114600.2653259
    1670148410.153850.3305292
    1670156650.1864850.37081127
    16701741050.235900.431134192
    16701921610.300900.504210282
    TBA12100.3351250.560267288
    1670211/02660.3811250.645324451
    1670222/03420.4061250.690424566
    1670233/04180.4861250.760519676
    1670244/05320.5311250.815539814
    167026262.66460.5711550.974740974
    167027313.37790.656155.9808961,140
    167029373.79310.7021551.04010771,344
    167030444.411020.7831501.10513781,654
    167031535.313250.8051551.20517311,901
    167032646.416000.9001551.28520902,446
    167033777.719240.9901551.38025232,833
    TBA929.223001.1151551.47130603162
    167035111127501.1702101.76036714,178
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    #12 and #10 AWG are not approved for CSA RW90
    Table 2 – Electrical and Engineering Data
    Stock NumberCond. SizeMin Bending RadiusMax Pull TensionDC Resistance @ 25°CInductive Reactance @ 60HzAllowable Ampacity At 75°C†Allowable Ampacity At 90°C†
    AWG/KcmilinchlbΩ/1000ftΩ/1000ftAmpAmp
    571253121.68521.6900.0412530
    560057102.12831.0400.0383540
    16701482.631320.6540.0395055
    16701562.982100.4190.0376575
    16701743.373340.2630.0358595
    16701924.035310.1660.033115130
    TBA14.486700.1320.032130145
    1670211/05.528450.1050.034150170
    1670222/05.7610650.08340.033175195
    1670233/05.8113420.06620.032200225
    1670244/07.7316930.05250.031230260
    167026262.67.7321010.04260.029267304
    167027313.38.3625060.03570.034298332
    167029373.78.7129900.03000.033323365
    167030444.49.3235550.02520.031358405
    167031535.39.6042820.02090.031394446
    167032646.410.2851710.01740.031439496
    167033777.710.9162220.01460.029483543
    TBA929.211.7774340.01210.029529594
    167035111114.0888880.01200.032570648
    + Ampacities based on Table 310.15(B)(16) of the National Electrical Code® for not more Ambient Temperature of 30°C (86°F) than three current-carrying conductors in raceway, cable or earth. Based on
    ++ Ampacities based on Table 310.15(B)(17) of the National Electrical Code® Allowable Ampacities of Single-Insulated Conductors Rated Up to and Including 2000 Volts in Free Air. Based on Ambient Temperature of 30°C (86°F)

    Revision: 3.0.00M