SPEC 42030

ETFE 200°C 300V UL 10109

UL/CSA Approved Lead Wire, Temp Rating 200°C

...

Construction:

  1. Conductor:Stranded tinned, annealed copper per ASTM B33
  2. Insulation:Extruded ETFE fluoropolymer jacket

Applications and Features:

Used for wiring of electric heaters, appliances, thermocouples, gas igniters, electrical and electronic components, and other products up to 200°C. Excellent chemical resistance, excellent resistance to fluids, and low coefficient of friction makes installation easier. Good mechanical strength. Available in all colors.

Specifications:

  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL AWM Appliance wire approvals as listed in Table 1
  • RoHS-3 Complies with European Directive 2015/863
  • Table 1 – Weights and Measurements
    Stock NumberCond. SizeCond. StrandsInsul. ThicknessApprox. ODApprox. WeightTemp. RatingStandard (UL or other)
    AWG/Kcmilstrandmilinchlb/1000ft°CStyle/Type
    CZ243X24*7/.00860.038220010109
    CZ223X22*7/.01060.044320010109
    CZ203X20*7/.012660.052420010109
    CZ183A187/.015960.062720010109
    CZ163A167/.019280.072920010109
    CZ143A147/.024280.0871420010109
    CZ123A1219/.0179100.1152320010109
    CZ103A1037/.0159100.1393520010109
    CZ083A854/.0179250.2206520010109
    CZ063A684/.0179250.2439720010109
    CZ043A4133/.0177250.31915020010109
    CZ023A2133/.0223350.40824320010109
    CZ013A1259/.0177350.45130320010109
    CZ1T3A1/0259/.0202450.51838920010109
    CZ2T3A2/0259/.0229450.57148420010109
    CZ3T3A3/0259/.0255450.61056520010109
    CZ4T3A4/0259/.0286450.69572620010109
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    Dimensions and weights for other cable configurations are available upon request.
    *NPC Conductor required for 200°C Rating
    Table 2 – Weights and Measurements (Metric)
    Stock NumberCond. SizeCond. StrandsInsul. ThicknessApprox. ODApprox. WeightTemp. RatingStandard (UL or other)
    AWG/Kcmilstrandmmmmkg/km°CStyle/Type
    CZ243X24*7/.0080.150.97320010109
    CZ223X22*7/.0100.151.12420010109
    CZ203X20*7/.01260.151.32620010109
    CZ183A187/.01590.151.571020010109
    CZ163A167/.01920.201.831320010109
    CZ143A147/.02420.202.212120010109
    CZ123A1219/.01790.252.923420010109
    CZ103A1037/.01590.253.535220010109
    CZ083A854/.01790.645.599720010109
    CZ063A684/.01790.646.1714420010109
    CZ043A4133/.01770.648.1022320010109
    CZ023A2133/.02230.8910.3636220010109
    CZ013A1259/.01770.8911.4645120010109
    CZ1T3A1/0259/.02021.1413.1657920010109
    CZ2T3A2/0259/.02291.1414.5072020010109
    CZ3T3A3/0259/.02551.1415.4984120010109
    CZ4T3A4/0259/.02861.1417.65108020010109

    Revision: 3.0.00M